News T3 2023 TBSHOOT IBM Sterling B2B Integrator Creating a user with less than 5 characters

Integration News

Troubleshooting
IBM Sterling B2B Integrator

Creating a user with less than 5 characters

PROBLEM

IBM Sterling B2B Integrator (SBI) allows user account creation atleast if it contains five characters. However, Are there any options to create a user with less than five characters?

RESOLVING THE PROBLEM

  • Stop SBI
  • Traverse to <SI_INSTALL_DIR>/properties folder and locate customer_overrides.properties file.
  • If customer_overrides.properties file does not exists then create one.
  • Add the below property into customer_overrides.properties file.
    userIdMinLength=4 (Ex: to create a user id with 4 characters)
  • Start SBI